Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir

  • Audited Supplier
  • 7 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Non-Contact Measurement: Uses ultrasonic technology for reliable measurement in dirty or corrosive liquid conditions.
  • High Accuracy: Level measurement accuracy of 0.5% with resolution up to 3mm or 0.1%.
  • Wide Measurement Range: Measures flow from 0.1 L/second up to 99999.99 m3/H with cumulative flow up to 4.29 billion m3.
  • Versatile Weir Compatibility: Designed for Parshall flume, rectangular weir, and triangular weir open channels.
  • Robust Protection Rating: Display meter IP67/IP65 and probe IP68 for harsh environments.
  • Flexible Communication: Supports RS485 Modbus protocol with optional 232 communication.
  • Customizable Materials: Standard ABS probe with optional PTFE material for corrosive environments.
  • OEM/ODM Services: Manufacturer offers both OEM and ODM services for customized solutions.

Product Images of Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir

Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir pictures & photos
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir pictures & photos
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir pictures & photos
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir pictures & photos
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir pictures & photos
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
  • Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
    Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
  • Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
    Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
  • Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
    Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
  • Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
    Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
  • Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
    Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir

Find Similar Products

Product Description

 ultrasonic open channel flow meter for parshall flume/rectangular weir/triangular weir 

                                                           open channel ultraosnic flow meter

 Description 

Ultrasonic open channel flow meter with a weir tank with the use of measuring the flow of water in the open
channel. Mainly used to measure the waste
 water treatment plant, sewage outfall enterprises, the city sewer
and water conservancy in the flow channels.

As the Company through the air using ultrasonic instruments to non-contact measurement method. Therefore,
under dirt, corrosive liquid condition, than contact type instrument, with higher reliability and durability.

 Specifications 

Function integrated type
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Split-type
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Measurement range 0.1 L/second ~ 99999.99 m3/H
Cumulative flow Max: 4,290,000,000.00 m3
Level maximum range 3m
Level Measurement Accuracy 0.5%
Resolution 3mm or 0.1%(take the bigger one)
Flow measurement accuracy Standard weir tank is 1 to 5% (weir tank and channels meet the national standard requirement)
Non-standard weir tank is 10 to 30 percent.
Analog Output 4-wire 4 ~ 20mA / 750Ω load
Relay output (Option) Group 2 AC 220V / 8A or DC 24V / 5A,
Power supply Standard 24VDC 100mA; optional 220V AC + 15% 50Hz.
Power supply (Optional item) 12VDC, battery-powered,
Operating ambient temperature Display Meter -20 ~ + 60 ºC, the probe -20 ~ + 80 ºC
Workplace stress Standard atmospheric pressure
Operating humidity ≤90% RH, non-condensing
Process temperature -20~80ºC;
Process pressure Standard atmospheric pressure
Communication Optional 485,232 communication, MODBUS protocol
Protection class Display IP67, probe IP68 Display meter IP65, probe IP68
Probe cable no Standard 10 meters and the maximum is 100 m
Probe mounting dimensions M48 × 2mm screw + supporting nuts
Probe material ABS is standard, and in a corrosive environment to use PTFE materials.

Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir

Open channel ultrasonic flow meter size:
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
 

Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir

Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Installation:

Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir
open channel ultrasonic flow meter open drain ultrasonic flow meter

Ultrasonic Open Channel Flow Meter for Parshall Flume/Rectangular Weir/Triangular Weir




 ultrasonic open channel flow meter for parshall flume/rectangular weir/triangular weir 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR235473". Items marked "verified" are certified.

Watch Video
Watch Video
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.
Yantai Auto Instrument Making Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 3, Hengshan Road, ETDZ, Yantai, China
verified Plant Area
4300 square meters
verified Number of Employees
43
verified Registered Capital
10,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Yantai Port

Our Production Capability & Technical Expertise

verified Main Products
Pressure Transmitter, Flow Meter, Level Transmitter
verified Production Machines
High and Low Temperature and Pressure Compensation Chamber, Welding Machine, Testing Equipment, Flow Calibration System, CNC, Oil Filling System
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
2 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
1994-11-28
Export Year
2015-11-04
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia, Domestic
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE, RoHS, Others

FAQ

What is the measurement accuracy?
Level measurement accuracy is 0.5%. Standard weir tank flow accuracy is 1-5%, while non-standard tanks range from 10-30%.
Can it measure corrosive liquids?
Yes, it uses non-contact ultrasonic measurement which is more reliable than contact types in corrosive conditions. PTFE probe material is available for such environments.
What are the power supply options?
Standard power is 24VDC. Optional supplies include 220V AC and 12VDC battery-powered options.
What is the maximum cable length?
The standard probe cable is 10 meters, with a maximum extendable length of 100 meters.
Does it support custom manufacturing?
Yes, the company offers both OEM and ODM services and can customize output signals and power supplies.
What communication protocols are supported?
It supports RS485 Modbus protocol, with optional 232 communication available.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now