Customization: | Available |
---|---|
Type: | Intelligent Pressure Transmitter |
Feature: | Intelligent |
Still deciding? Get samples of US$ 190/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Differential Pressure transmitter/Pressure Transmtiter
Introduction
The (differential) pressure transmitter is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. Outputs a 4~20mA DC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm.
Features:
Process Fluid | Liquid, Gas, Vapor |
Application | Differential Pressure, Gauge Pressure,Absolute Pressure |
Working Temperature | -25 to +95C |
Current Output | 4 - 20 mA 2 wires Har t Protocol |
Power Supply | 24VDC |
Ambient Temperature | -25 to +240C |
Process connections: | 1/4 - 18 NPT or 1/2 - 14 NPT |
Electrical Connections | 1/2"NPT or M20*1.5 |
Enclosure | IP65 |
Intrinsically Safe | Exia II C T6 |
Explosion proof | Exd II B T5 |
Details:
Dimension
Ordering Sheet
Item | Code | Specification |
AT3051DP | Differential Pressure Transmitter | |
AT3051GP | Gauge Pressure Transmitter | |
Measurement Range | 2 | 0-0.1~1.5 Kpa |
3 | 0~7.5 Kpa | |
4 | 0~37.4 Kpa | |
5 | 0~186.8 Kpa | |
6 | 0~690 Kpa | |
7 | 0~2068 Kpa | |
8 | 0~6890 Kpa | |
9 | 0~20680 Kpa | |
Output | S | 4-20mA, HART Protocol, Linear output |
J | 4-20mA, HART Protocol, Square root output(Range≥5kpa) | |
Diaphragm Material / Fill Fluid |
2 | Stainless Steel 316L Silicone Oil |
3 | Hastelloy C(range >3Kpa) Silicone Oil | |
A | Stainless Steel 316L Fluorine oil | |
Drain hole | B | Back of process flange or none |
U | Process flange side upper | |
L | Process flange side lower | |
Wetted O-ring Material | 7 | Buna-N (NBR) |
6 | Viton (FKM) (Temperature ≥-20ºC) | |
5 | Low Temperature Viton (FKM-GFLT) | |
Process Connection | H | 1/4'' NPT F |
Maximum Pressure Limit | 1 | 14 Mpa( 4Mpa for range 2) |
3 | 25 Mpa | |
5 | 32 Mpa | |
Cable Entry | 1 | M20*1.5 |
Mounting Bracket | B00 | None |
B01 | Tube-type Curved Bracket (carbon steel) | |
B02 | Wall mounting bracket (carbon steel) | |
B03 | Tube-type Flat Bracket (carbon steel) | |
B04 | Tube-type Curved Bracket (stainless steel) | |
B05 | Wall mounting bracket (stainless steel) | |
B06 | Tube-type Flat Bracket (stainless steel) | |
Optional | d | Intrinsically safe type, Flameproof (Exd IIC T4~T6) |
i | Intrinsically safe (Exia IIC T4~T6) | |
M3 | LCD display | |
D1 | Stainless steel drain valve or screw (2pcs) | |
C1 | 1/2'' NPT female waist flange (2sets) | |
C12 | 1/2'' NPT-M20*1.5-Φ14 pressure pipe (2sets) | |
C2 | M20*1.5 male thread T joint (2sets) | |
C21 | M20*1.5 T joint -Φ14 pressure pipe (2sets) | |
K1 | Degreasing treatment |